MX series

VX series main features

HIGH PERFORMANCES: high flow rates or pressure performances
WALL MOUNTING HOUSING: die cast aluminium housing coated with anti-corrosive epoxy paint

  • Stroke frequency adjustment 120 impulses / minute
  • Ceramic ball check valves
  • Reed “LIP” valve types for performance 05-20
  • Standard hose O 10 x 14 mm
  • Die-cast aluminium housing / IP65 rating
  • Epoxy anti-acid coating
  • PTFE diaphragm
  • Level control setting
  • Standard accessories
VX technical characteristics
Pump type rangeMax Flow / Max PressureStroke Length (mm)Output cc(ml) /strokePump head typeHose size (mm)Max suction (m)Max stroke freqPower/Current consumption
l/hbar
VX 05-205201,50,52PVC20b3/8″4×62,0160/min115 watts/0,48A
VX 10-10*10101,11,04PP 3/8″4×62,0160/min93 watts/0,39A
VX 20-052052,22,08PP20L 3/8″4×62,0160/min111 watts/0,48A
VX 30-043041,42,80PVC 1/2″10×141,5180/min124 watts/0,54A
VX 50-035031,74,60PVC 1/2″10×141,5180/min124 watts/0,54A
VX 80-018012,47,40PVC 1/2″10×141,5180/min124 watts/0,54A
Hose size: 10 x 14 mmMax suction lift: 2 m
Power supply: 230Vac-single phase 50-60 HzAVAILABLE: 110 Vac – single phase 60 Hz
VX liquid ends
WETTED PARTSSTANDARD VERSIONUPON REQUEST
Pump headPP MEMO 1 – MEMO 2PVDF; PMMA MEMO 3 / NOTE; AISI 316
Ball check valvepe check valveCERAMICAISI 316
DiaphragmPTFE——
Pump head Nipples / Hose NutPPPVDF
Seals / O-ringsFPMEPDM
Injection FittingPPPVDF
Injection No-Return Valve (sleeve type)FPMEPDM
Foot Valve Lip typeFPMEPDM
Filter body / Fitting-Nipple / Filtering mediaPE / PP / GlasswoolPVDF
Suction Hose/Air Bleed hose 10x14mmPVC flexiblePVDF; PTFE
Discharge Hose 10x14mmPE semi- flexiblePVDF; PTFE
OTHER OPTIONS AND SPECIAL CONFIGURATIONS UPON REQUEST:
Reed type “Lip” valveCERAMIC / PPCERAMIC / PVDF
Ball check Injection and Foot Valves / FittingCERAMIC / PPCERAMIC / PVDF
PVDF Spring Injection ball Valve / Fitting MEMO 4PVDF spring / CERAMIC / PPPVDF spring / CERAMIC / PVDF
Automatic autobleed pump headPVDF AUTO BLEED NOTE——
Aggressive chemicals configurationPVDF acid configuration MEMO 4——

MEMO 1: pump head type 03-20 and 22-02 do not feature air bleed valve.

MEMO 2: type 03-20 mounts PVC pump headls FPM (EPDM or PTFE), Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses.

MEMO 3: polymer viscous liquid configuration PMMA pump head, Ceramic ball checks (O11), Fittings PP 3/4”, o-rings/seals FPM or EPDM, Injection fitting and Strainer (without no- return valve), hoses PVC flexible 10×14.

MEMO 4: available only for 10-10 and 20-05 types.

MEMO 5: aggressive chemical configuration PVDF pump head/fittings, double Ceramic ball check valves, o-rings/seals FPM (EPDM or PTFE), Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses.

NOTE: Using AUTO-BLEED and Polymer PMMA configuration, pump pressure performance decreases of about 50%.

Models / dosing modes

Constant-ON/OFF mode - Analog controls

CONSTANT — ON/OFF pumps for those application where a simple pump at low cost is required but keeping maximum reliability. Pump flow rate is obtained by adjusting pulse frequency percentage (%). It also features reduction frequency scale range 1/5 reducing range from 100% to 20%. Available 12—24Vdc (limited flow rate range).

C/A
  • Constant flow rate / ON-OFF mode (also called Manual mode).
  • Strokes frequency adjustment 0 / 100%.
  • Frequency reduction ratio 100% / 20%.
  • Analog controls.
  • 2 LED display status: power and pulses.
Multifunction dosing mode pump
MF/D
  • Multifunction dosing pumps including most dosing operations modes.
  • Microcontroller technology, display LCD and digital controls.
  • Strokes frequency adjustment 0÷100%.
  • Proportional to external digital pulses: divider n : 1; multiplier 1xN.
  • Proportional to external analog signal 0…4 mA÷20mA or reverse.
  • PPM dosing mode
  • Constant mode with digital adjustment: imp/min; imp/hour; imp/day.
  • Digital timer, weekly and daily programming.
  • Sequence strokes/ injection with flow sensor (sensor on request).
  • Level alarm output contact: NO/NC.
  • Level control (Level switch upon request).
  • Available with double level control.
  • Available 12-24Vdc (limited flow rate range).