MX series

MX series main features
WALL MOUNTING HOUSING: includes a support bracket for easy quick mounting.
SMALL DIMENSIONS: ready also for mounting into small cabinets and small environments.
PRICE QUALITY: the new design allows to have a more competitive price with same quality of FX series.
MX series mounts CERAMIC ball check valves.
- Ceramic ball check valves;
- Standard hose 4×6 mm;
- Plastic housing PP reinforced – IP65 rating;
- Stroke frequency adjustment 120 impulses / minute;
- PTFE diaphragm / Air Bleed valve for priming;
- Standard accessories.
Technical characteristics
Pump type range | Max Flow / Max Pressure | Start up* performance | Frequency imp/min | Output cc(ml) /stroke | Pump head type | Valves types | ||
---|---|---|---|---|---|---|---|---|
l/h | bar | l/h | bar | |||||
MX 1,5-10 | 1,5 | 10 | 1,5 | 10 | 120 | 0,21 | PP 3/8″ | Ball checks |
MX 2,5-15 | 2,5 | 15 | 2,4 | 15 | 120 | 0,34 | PP 3/8″ | Ball checks |
MX 5,5-07 | 5,5 | 7 | 6 | 7 | 120 | 0,77 | PP 3/8″ | Ball checks |
MX 07-04 | 7 | 4 | 7 | 4 | 120 | 0,98 | PP 3/8″ | Ball checks |
Hose size: 4 x 6 mm (available 6×8 fittings) | Max suction lift: 2 m | |||||||
Power consumption: MX 37 watt | Current consumption: MX 0,16 Amp |
*NOTE: “Start up” performances are available when the pump starts the operations and are constant only if duties are not continuous (working for time periods not over 20/30 min and with at least 15 min rest).
Liquid ends
WETTED PARTS | STANDARD VERSION | UPON REQUEST |
Pump head | PP | PVDF; PMMA MEMO 1 / NOTE; AISI 316 |
Ball check valve | CERAMIC (MX series) | AISI 316 |
Diaphragm | PTFE | —— |
Pump head Nipples / Hose Nut | PP | PVDF |
Seals / O-rings | FPM | EPDM |
Injection Fitting | PP | PVDF |
Injection No-Return Valve (sleeve type) | FPM | EPDM |
Foot Valve Lip type | FPM | EPDM |
Filter body / Fitting-Nipple / Filtering media | PE / PP / Glasswool | PVDF |
Suction Hose/Air Bleed hose 4x6mm | PVC flexible | PVDF; PTFE |
Discharge Hose 4x6mm | PE semi- flexible | PVDF; PTFE |
OTHER OPTIONS AND SPECIAL CONFIGURATIONS UPON REQUEST: | ||
Reed type “Lip” valve | FPM (Viton â) | EPDM (Dutralâ) |
Ball check Injection and Foot Valves / Fitting | CERAMIC / PP | CERAMIC / PVDF |
PVDF Spring Injection ball Valve / Fitting | PVDF spring / CERAMIC / PP | PVDF spring / CERAMIC / PVDF |
Automatic autobleed pump head | PVDF AUTO BLEED NOTE | —— |
Aggressive chemicals configuration | PVDF acid configuration MEMO2 | —— |
MEMO 1: polymer viscous liquid configuration PMMA pump head, Ceramic ball checks (Ø11), Fittings PP 3/4”, o-rings / seals FPM or EPDM, Injection fitting and Strainer (without no- return valve), hoses PVC flexible 10×14.
MEMO 2: aggressive chemical configuration PVDF pump head/fittings, double Ceramic ball check valves, o-rings/seals FPM (EPDM or PTFE), Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses.
NOTE Using AUTO-BLEED or Polymer PMMA configuration, pump pressure performance decreases of about 50%.
Models / dosing modes
Constant-ON/OFF mode - Analog controls

C/A
Constant-ON/OFF pumps for those application where a simple pump at low cost is required but keeping maximum reliability. Pump flow rate is obtained by adjusting pulse frequency percentage (%). It also features reduction frequency scale range 1/5 reducing range from 100% to 20%. Available 12-24Vdc (limited flow rate range):
- Constant flow rate / ON-OFF mode (also called Manual mode);
- Strokes frequency adjustment 0 / 100%;
- Frequency reduction ratio 100% / 20%;
- Analog controls;
- 2 LED display status: power and pulses.

C/AL
- Constant flow rate – ON/OFF (Manual) with level control
- Provided with level control connector and floating level switch
- Other characteristics as above FX-FXS C/A
- 3 LED display status: power, pulses and level alarm
- Available with double level control
Constant mode - Digital controls

C/D
Pump flow rate is obtained by adjusting pulse frequency (%) by digital controls
- Digital Constant flow rate / ON-OFF mode (Manual);
- Stroke Frequency adjustment 0÷100%; imp/min; imp/hour; imp/day;
- Microcontroller technology;
- Digital controls and display;
- Level control (Level switch upon request);
- Available with double level control.
Proportional to analog ma current signal

CS/D
Pump flow rate is obtained by adjusting pulse frequency (%) by digital controls
- Proportional dosing pump to remote mA signal;
- Selection range 0/4…÷20mA or reverse;
- Constant modes operations;
- Strokes frequency adjustment 0÷100%;
- Microcontroller technology, display and digital controls;
- 2 LED display status: power, pulses and level;
- Level control (Level switch upon request).
Proportional to digital contact

P/D
- Proportional dosing pump to external digital pulses, (e.g.pulse water meters or equipment releasing voltage free pulse contacts)
- Constant modes operations
- Strokes frequency adjustment 0÷100%
- Microcontroller technology, display and digital controls
- 3 LED display status: power, pulses and level
- Level control (Level switch upon request)
- Available upon request PPM dosing mode
For available Pulse water meters
P/D+
- Sequence strokes/ injection with flow sensor (latter on request)
- Other characteristics as above MX P/D
Proportional modes:
- Divider n1 (n= pulses received /1= injection
- Multiplier 1xN (1=pulse received *N= injections)
- Multiplier 1xN M (with Memory)
- Pacing 1:1 (1 pulse received/1 injections)
Multifunction dosing mode pump

MF
- Multifunction dosing pumps including most dosing operations modes
- Microcontroller technology, display LCD and digital controls
- Strokes frequency adjustment 0÷100%
- Proportional to external digital pulses: divider n : 1; multiplier 1xN
- Proportional to external analog signal 0…4 mA÷20mA or reverse
- PPM dosing mode
- Constant mode with digital adjustment: imp/min; imp/hour; imp/day
- Digital timer, weekly and daily programming
- Sequence strokes/ injection with flow sensor (sensor on request)
- Level alarm output contact: NO/NC
- Level control (Level switch upon request)
- Available with double level control
- Available 12-24Vdc (limited flow rate range)
Dosing pump with build-in proportional multiparameter controller

CTRL3
Three different controllers and a dosing pump into one enclosure with great advantage to stock only one model for 3 measuring parameters.
pH: measuring range 0÷14,00 pH (resolution 0,01pH)
RX (ORP): measuring range -1000÷ +1400 mV (resolution 1mV)
Free chlorine*: range 0÷20,00 ppm (resolution 0,1ppm)
*CL controller is suitable either with amperometric-potentiostatic membrane Chlorine sensors or open Chlorine cells (latter on request)
- Microcontroller technology, back-lit LCD display, digital controls
- Injection frequency adjustment
- Connectors: BNC for electrode and 4 pole IP65 for CL sensors
- 2 Reset modes: full reset — partial reset keeping calibration settings
- Level control (Level switch upon request).
- Proportional mode range value selection
- Delay adjustment — Delay at powering ON (electrodes polarization)
- Stroke length adjustment for injected volume regulation (only FX series)
- Hysteresis regulation
- Password setting
- Calibration of mA output
- 4÷20 mA output for chart recorder
- Alarm functions: Over dosing alarm value to prevent excess of chemical injection
- Alarm for minimum or Maximum time for reaching set point
- Direct or Reverse mode (Alkaline or Acid, Oxidant or Reducing RX)
- Stand-by mode for cleaning electrodes and sensors or re-calibration
- Temperature measurement °C or °F
- Suitable for Temperature probe PT100
- Setting for proximity switch to stop operations in case of no water (instead of level)
- Alarm functions and setting with relay output
Dosing pump with build-in proportional dual parameter controller

CTRL2
Two different controllers and a dosing pump into one enclosure with great advantage to stock only one model for 2 measuring parameters.
pH: measuring range 0÷14,00 pH (resolution 0,01pH)
RX: measuring range -1000÷ +1400 mV (resolution 1mV)
- Microcontroller technology, back-lit LCD display, digital controls
- Injection frequency adjustment
- 2 Reset modes: full reset — partial reset keeping calibration settings
- Stroke length adjustment for injected volume regulation (only FX serie)
- Level control (Level switch upon request).
- Proportional mode range value selection
- Delay adjustment — Delay at powering ON (electrodes polarization)
- Hysteresis regulation
- Password setting
- Direct or Reverse mode (Alkaline or Acid, Oxidant or Reducing RX)
- Stand-by mode for cleaning electrodes and sensors or re-calibration