MX series

FX series mounting modes

FX series is what can be called “all round” combining great quality at attractive price Client can choose between foot mounting and wall mounting.

Foot mounting
Wall mounting
FX series controls

FX series operations are guaranteed by stroke frequency and stroke length adjustment.

Stroke frequency adjustment

FX series control operations feature two operating controls versions:
— Analog controls with L.E.D. indicators
— Digital controls with display and L.E.D. indicators.

Stroke length adjustment

It varies the single stroke volume displacement offering the advantage of double flow rate regulation: pulse frequency adjustment and stroke length allowing accurate dosing operations. Recommended stroke adjustment rate: 20% — 100%

FXS series WITHOUT stroke adjustment

FXS series available without stroke adjustment
(on request). Recommended for WALL mounting applications where the competitive price is the most important requirement.

FX series main features

FOOT MOUNTING HOUSING: PP plastic housing for horizontal installation (available wall support bracket) SMALL / MEDIUM performances: flow rates from 1,5 to 22 l/h / pressure up to 20 bar WIDE RANGE OF APPLICATIONS: from water treatment to swimming pools and industrial processes Two ranges available: FX and FXS.

  • Stroke frequency adjustment 120 impulses / minute
  • Stroke adjustment for injected volume (only FX)
  • Ceramic ball check valves
  • Standard hose O 4×6 mm
  • Plastic housing PP reinforced – IP65 rating
  • PTFE diaphragm / Air Bleed valve for priming
  • Standard accessories
Horizontal (foot) mounting
Wall mounting with support bracket
Technical characteristics
Pump type rangeMax Flow / Max PressureStart up* performanceStroke Length (mm)Output cc(ml) /strokePump head typePower/Current consumption
l/hbarl/hbar
FX 1,5-101,5101,5100,800,21PP 3/8″37 watts/0,16 A
FX 2,5-152,5152,4150,800,34PP 3/8″37 watts/0,16 A
FX 03-203203,6201,000,49PVC20b 3/8″58 watts/0,25 A
FX 5,5-075,57671,000,77PP 3/8″37 watts/0,16 A
FX 05-126126,2121,000,84PP 3/8″58 watts/0,25 A
FX 08-09897,591,401,10PP 3/8″58 watts/0,25 A
FX 14-0414417,642,201,96PP 3/8″58 watts/0,25 A
FX 22-022222322,203,08PP20L 3.8″58 watts/0,25 A
Hose size: 4 x 6 mm (available 6×8 fittings)Max suction lift: 2 m
Power supply: 230Vac-single phase 50-60 HzMax strokes frequency: 120 per minute
AVAILABLE: 12Vdc-24Vdc are available only with following models: C/A, C/AL, MF, CTRL, Types up to 08-09 types

*NOTE: “Start up” performances are available when the pump starts the operations and are constant only if duties are not continuous (working for time periods not over 20/30 min and with at least 15 min rest).

FX series liquid ends
WETTED PARTSSTANDARD VERSIONUPON REQUEST
Pump headPPPVDF; PMMA MEMO 1 / NOTE; AISI 316
Ball check valvepe check valveCERAMICAISI 316
DiaphragmPTFE——
Pump head Nipples / Hose NutPPPVDF
Seals / O-ringsFPMEPDM
Injection FittingPPPVDF
Injection No-Return Valve (sleeve type)FPMEPDM
Foot Valve Lip typeFPMEPDM
Filter body / Fitting-Nipple / Filtering mediaPE / PP / GlasswoolPVDF
Suction Hose/Air Bleed hose 4x6mmPVC flexiblePVDF; PTFE
Discharge Hose 4x6mmPE semi- flexiblePVDF; PTFE
OTHER OPTIONS AND SPECIAL CONFIGURATIONS UPON REQUEST:
Reed type “Lip” valveCERAMIC / PPCERAMIC / PVDF
Ball check Injection and Foot Valves / FittingCERAMIC / PPCERAMIC / PVDF
PVDF Spring Injection ball Valve / FittingPVDF spring / CERAMIC / PPPVDF spring / CERAMIC / PVDF
Automatic autobleed pump headPVDF AUTO BLEED NOTE——
Aggressive chemicals configurationPVDF acid configuration MEMO 2——

MEMO 1: polymer viscous liquid configuration PMMA pump head, Ceramic ball checks (O11), Fittings PP 3/4”, o-rings / seals FPM or EPDM, Injection fitting and Strainer (without no- return valve), hoses PVC flexible 10×14.

MEMO 2: aggressive chemical configuration PVDF pump head/fittings, double Ceramic ball check valves, o-rings/seals FPM (EPDM or PTFE), Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses

NOTE: Using AUTO-BLEED or Polymer PMMA configuration, pump pressure performance decreases of about 50%

Models / dosing modes

Constant-ON/OFF mode - Analog controls
C/A

Constant-ON/OFF pumps for those application where a simple pump at low cost is required but keeping maximum reliability. Pump flow rate is obtained by adjusting pulse frequency percentage (%). It also features reduction frequency scale range 1/5 reducing range from 100% to 20%. Available 12-24Vdc (limited flow rate range):

  • Constant flow rate / ON-OFF mode (also called Manual mode);
  • Stroke adjustment for injected volume, foot mounting;
  • Strokes frequency adjustment 0 / 100%;
  • Frequency reduction ratio 100% / 20%;
  • Analog controls;
  • 2 LED display status: power and pulses.
C/AL
  • Constant flow rate – ON/OFF (Manual) with level control
  • Provided with level control connector and floating level switch
  • Other characteristics as above FX-FXS C/A
  • 3 LED display status: power, pulses and level alarm
  • Available with double level control
Constant mode - Digital controls
C/D

Pump flow rate is obtained by adjusting pulse frequency (%) by digital controls

  • Digital Constant flow rate / ON-OFF mode (Manual);
  • Stroke Frequency adjustment 0÷100%; imp/min; imp/hour; imp/day;
  • Microcontroller technology;
  • Digital controls and display;
  • Level control (Level switch upon request);
  • Available with double level control.
Proportional to analog ma current signal
CS/D

Pump flow rate is obtained by adjusting pulse frequency (%) by digital controls

  • Proportional dosing pump to remote mA signal;
  • Selection range 0/4…÷20mA or reverse;
  • Constant modes operations;
  • Strokes frequency adjustment 0÷100%;
  • Microcontroller technology, display and digital controls;
  • 2 LED display status: power, pulses and level;
  • Level control (Level switch upon request).
Proportional to digital contact
P/D
  • Proportional dosing pump to external digital pulses, (e.g.pulse water meters or equipment releasing voltage free pulse contacts)
  • Constant modes operations
  • Strokes frequency adjustment 0÷100%
  • Microcontroller technology, display and digital controls
  • 3 LED display status: power, pulses and level
  • Level control (Level switch upon request)
  • Available upon request PPM dosing mode

For available Pulse water meters

P/D+
  • Sequence strokes/ injection with flow sensor (latter on request)
  • Other characteristics as above MX P/D
Proportional modes:
  • Divider n1 (n= pulses received /1= injection
  • Multiplier 1xN (1=pulse received *N= injections)
  • Multiplier 1xN M (with Memory)
  • Pacing 1:1 (1 pulse received/1 injections)
Multifunction dosing mode pump
MF
  • Multifunction dosing pumps including most dosing operations modes
  • Microcontroller technology, display LCD and digital controls
  • Strokes frequency adjustment 0÷100%
  • Proportional to external digital pulses: divider n : 1; multiplier 1xN
  • Proportional to external analog signal 0…4 mA÷20mA or reverse
  • PPM dosing mode
  • Constant mode with digital adjustment: imp/min; imp/hour; imp/day
  • Digital timer, weekly and daily programming
  • Sequence strokes/ injection with flow sensor (sensor on request)
  • Level alarm output contact: NO/NC
  • Level control (Level switch upon request)
  • Available with double level control
  • Available 12-24Vdc (limited flow rate range)
Dosing pump with build-in proportional multiparameter controller
CTRL3

Three different controllers and a dosing pump into one enclosure with great advantage to stock only one model for 3 measuring parameters.
pH: measuring range 0÷14,00 pH (resolution 0,01pH)
RX (ORP): measuring range -1000÷ +1400 mV (resolution 1mV)
Free chlorine*: range 0÷20,00 ppm (resolution 0,1ppm)
*CL controller is suitable either with amperometric-potentiostatic membrane Chlorine sensors or open Chlorine cells (latter on request)

  • Microcontroller technology, back-lit LCD display, digital controls
  • Injection frequency adjustment
  • Connectors: BNC for electrode and 4 pole IP65 for CL sensors
  • 2 Reset modes: full reset — partial reset keeping calibration settings
  • Level control (Level switch upon request).
  • Proportional mode range value selection
  • Delay adjustment — Delay at powering ON (electrodes polarization)
  • Stroke length adjustment for injected volume regulation (only FX series)
  • Hysteresis regulation
  • Password setting
  • Calibration of mA output
  • 4÷20 mA output for chart recorder
  • Alarm functions: Over dosing alarm value to prevent excess of chemical injection
  • Alarm for minimum or Maximum time for reaching set point
  • Direct or Reverse mode (Alkaline or Acid, Oxidant or Reducing RX)
  • Stand-by mode for cleaning electrodes and sensors or re-calibration
  • Temperature measurement °C or °F
  • Suitable for Temperature probe PT100
  • Setting for proximity switch to stop operations in case of no water (instead of level)
  • Alarm functions and setting with relay output
Dosing pump with build-in proportional dual parameter controller
CTRL2

Two different controllers and a dosing pump into one enclosure with great advantage to stock only one model for 2 measuring parameters.
pH: measuring range 0÷14,00 pH (resolution 0,01pH)
RX: measuring range -1000÷ +1400 mV (resolution 1mV)

  • Microcontroller technology, back-lit LCD display, digital controls
  • Injection frequency adjustment
  • 2 Reset modes: full reset — partial reset keeping calibration settings
  • Stroke length adjustment for injected volume regulation (only FX serie)
  • Level control (Level switch upon request).
  • Proportional mode range value selection
  • Delay adjustment — Delay at powering ON (electrodes polarization)
  • Hysteresis regulation
  • Password setting
  • Direct or Reverse mode (Alkaline or Acid, Oxidant or Reducing RX)
  • Stand-by mode for cleaning electrodes and sensors or re-calibration