VX series



VX series Main features


HIGH PERFORMANCES: high flow rates or pressure performances
WALL MOUNTING HOUSING: die cast aluminium housing coated with anti-corrosive epoxy paint
  • Stroke frequency adjustment 120 impulses / minute
  • Ceramic ball check valves
  • Reed “LIP” valve types for performance 05-20
  • Standard hose O 10 x 14 mm
  • Die-cast aluminium housing / IP65 rating
  • Epoxy anti-acid coating
  • PTFE diaphragm
  • Level control setting
  • Standard accessories

Technical characteristics


Pump type range Max Flow / Max Pressure Stroke Length (mm) Output cc(ml) /stroke Pump head type Hose size (mm) Max suction (m) Max stroke freq Power/Current consumption
l/h bar
VX 05-20 5 20 1,5 0,52 PVC20b3/8" 4x6 2,0 160/min 115 watts/0,48A
VX 10-10* 10 10 1,1 1,04 PP 3/8" 4x6 2,0 160/min 93 watts/0,39A
VX 20-05 20 5 2,2 2,08 PP20L 3/8" 4x6 2,0 160/min 111 watts/0,48A
VX 30-04 30 4 1,4 2,80 PVC 1/2" 10x14 1,5 180/min 124 watts/0,54A
VX 50-03 50 3 1,7 4,60 PVC 1/2" 10x14 1,5 180/min 124 watts/0,54A
VX 80-01 80 1 2,4 7,40 PVC 1/2" 10x14 1,5 180/min 124 watts/0,54A
Hose size: 10 x 14 mm Max suction lift: 2 m
Power supply: 230Vac-single phase 50-60 Hz AVAILABLE: 110 Vac – single phase 60 Hz

Liquid ends


WETTED PARTS STANDARD VERSION UPON REQUEST
Pump head PP MEMO 1 – MEMO 2 PVDF; PMMA MEMO 3 / NOTE; AISI 316
Ball check valvepe check valve CERAMIC AISI 316
Diaphragm PTFE ------
Pump head Nipples / Hose Nut PP PVDF
Seals / O-rings FPM EPDM
Injection Fitting PP PVDF
Injection No-Return Valve (sleeve type) FPM EPDM
Foot Valve Lip type FPM EPDM
Filter body / Fitting-Nipple / Filtering media PE / PP / Glasswool PVDF
Suction Hose/Air Bleed hose 10x14mm PVC flexible PVDF; PTFE
Discharge Hose 10x14mm PE semi- flexible PVDF; PTFE
OTHER OPTIONS AND SPECIAL CONFIGURATIONS UPON REQUEST:
Reed type “Lip” valve CERAMIC / PP CERAMIC / PVDF
Ball check Injection and Foot Valves / Fitting CERAMIC / PP CERAMIC / PVDF
PVDF Spring Injection ball Valve / Fitting MEMO 4 PVDF spring / CERAMIC / PP PVDF spring / CERAMIC / PVDF
Automatic autobleed pump head PVDF AUTO BLEED NOTE ------
Aggressive chemicals configuration PVDF acid configuration MEMO 4 ------

MEMO 1: pump head type 03-20 and 22-02 do not feature air bleed valve.

MEMO 2: type 03-20 mounts PVC pump headls FPM (EPDM or PTFE), Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses.

MEMO 3: polymer viscous liquid configuration PMMA pump head, Ceramic ball checks (O11), Fittings PP 3/4”, o-rings/seals FPM or EPDM, Injection fitting and Strainer (without no- return valve), hoses PVC flexible 10x14.

MEMO 4: available only for 10-10 and 20-05 types.

MEMO 5: aggressive chemical configuration PVDF pump head/fittings, double Ceramic ball check valves, o-rings/seals FPM (EPDM or PTFE), Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses.

NOTE: Using AUTO-BLEED and Polymer PMMA configuration, pump pressure performance decreases of about 50%.


DOSING MODES


CONSTANT-ON/OFF MODE — ANALOG CONTROLS


CONSTANT — ON/OFF pumps for those application where a simple pump at low cost is required but keeping maximum reliability. Pump flow rate is obtained by adjusting pulse frequency percentage (%). It also features reduction frequency scale range 1/5 reducing range from 100% to 20%. Available 12—24Vdc (limited flow rate range)

C/A

  • Constant flow rate / ON-OFF mode (also called Manual mode)
  • Strokes frequency adjustment 0 / 100%
  • Frequency reduction ratio 100% / 20%
  • Analog controls
  • 2 LED display status: power and pulses

MULTIFUNCTION DOSING MODE PUMP


MF/D

  • Multifunction dosing pumps including most dosing operations modes
  • Microcontroller technology, display LCD and digital controls
  • Strokes frequency adjustment 0÷100%
  • Proportional to external digital pulses: divider n : 1; multiplier 1xN
  • Proportional to external analog signal 0…4 mA÷20mA or reverse
  • PPM dosing mode
  • Constant mode with digital adjustment: imp/min; imp/hour; imp/day
  • Digital timer, weekly and daily programming
  • Sequence strokes/ injection with flow sensor (sensor on request)
  • Level alarm output contact: NO/NC
  • Level control (Level switch upon request)
  • Available with double level control
  • Available 12-24Vdc (limited flow rate range)