MX series Main features


WALL MOUNTING HOUSING: includes a support bracket for easy quick mounting
SMALL DIMENSIONS: ready also for mounting into small cabinets and small environments
PRICE QUALITY: the new design allows to have a more competitive price with same quality of FX series
MX series mounts CERAMIC ball check valves
  • Ceramic ball check valves
  • Standard hose 4x6 mm
  • Plastic housing PP reinforced – IP65 rating
  • Stroke frequency adjustment 120 impulses / minute
  • PTFE diaphragm / Air Bleed valve for priming
  • Standard accessories

Technical characteristics


Pump type range Max Flow / Max Pressure Start up* performance Frequency imp/min Output cc(ml) /stroke Pump head type Valves types
l/h bar l/h bar
MX 1,5-10 1,5 10 1,5 10 120 0,21 PP 3/8" Ball checks
MX 2,5-15 2,5 15 2,4 15 120 0,34 PP 3/8" Ball checks
MX 5,5-07 5,5 7 6 7 120 0,77 PP 3/8" Ball checks
MX 07-04 7 4 7 4 120 0,98 PP 3/8" Ball checks
Hose size: 4 x 6 mm (available 6x8 fittings) Max suction lift: 2 m
Power consumption: MX 37 watt Current consumption: MX 0,16 Amp

*NOTE: “Start up” performances are available when the pump starts the operations and are constant only if duties are not continuous (working for time periods not over 20/30 min and with at least 15 min rest).

Liquid ends


WETTED PARTS

STANDARD VERSION

UPON REQUEST

Pump head

PP

PVDF; PMMA MEMO 1 / NOTE; AISI 316

Ball check valve

CERAMIC (MX series)

AISI 316

Diaphragm

PTFE

------

Pump head Nipples / Hose Nut

PP

PVDF

Seals / O-rings

FPM

EPDM

Injection Fitting

PP

PVDF

Injection No-Return Valve (sleeve type)

FPM

EPDM

Foot Valve Lip type

FPM

EPDM

Filter body / Fitting-Nipple / Filtering media

PE / PP / Glasswool

PVDF

Suction Hose/Air Bleed hose 4x6mm

PVC flexible

PVDF; PTFE

Discharge Hose 4x6mm

PE semi- flexible

PVDF; PTFE

OTHER OPTIONS AND SPECIAL CONFIGURATIONS UPON REQUEST:

Reed type “Lip” valve

FPM (Viton â)

EPDM (Dutralâ)

Ball check Injection and Foot Valves / Fitting

CERAMIC / PP

CERAMIC / PVDF

PVDF Spring Injection ball Valve / Fitting

PVDF spring / CERAMIC / PP

PVDF spring / CERAMIC / PVDF

Automatic autobleed pump head

PVDF AUTO BLEED NOTE

------

Aggressive chemicals configuration

PVDF acid configuration MEMO2

------


MEMO 1: polymer viscous liquid configuration PMMA pump head, Ceramic ball checks (Ø11), Fittings PP 3/4”, o-rings / seals FPM or EPDM,

Injection fitting and Strainer (without no- return valve), hoses PVC flexible 10x14.


MEMO 2: aggressive chemical configuration PVDF pump head/fittings, double Ceramic ball check valves, o-rings/seals FPM (EPDM or PTFE),

Foot and Injection no-return valve PVDF spring / Ceramic ball check, PVDF suction/discharge hoses


NOTE Using AUTO-BLEED or Polymer PMMA configuration, pump pressure performance decreases of about 50%


MODELS / DOSING MODES


CONSTANT-ON/OFF MODE - ANALOG CONTROLS


C/A

CONSTANT-ON/OFF pumps for those application where a simple pump at low cost is required but keeping maximum reliability. Pump flow rate is obtained by adjusting pulse frequency percentage (%). It also features reduction frequency scale range 1/5 reducing range from 100% to 20%. Available 12-24Vdc (limited flow rate range)
  • Constant flow rate / ON-OFF mode (also called Manual mode)
  • Strokes frequency adjustment 0 / 100%
  • Frequency reduction ratio 100% / 20%
  • Analog controls
  • 2 LED display status: power and pulses

C/AL

  • Constant flow rate – ON/OFF (Manual) with level control
  • Provided with level control connector and floating level switch
  • Other characteristics as above FX-FXS C/A
  • 3 LED display status: power, pulses and level alarm
  • Available with double level control

CONSTANT MODE - DIGITAL CONTROLS


C/D

Pump flow rate is obtained by adjusting pulse frequency (%) by digital controls
  • Digital Constant flow rate / ON-OFF mode (Manual)
  • Stroke Frequency adjustment 0÷100%; imp/min; imp/hour; imp/day
  • Microcontroller technology
  • Digital controls and display
  • Level control (Level switch upon request)
  • Available with double level control

PROPORTIONAL TO ANALOG mA CURRENT SIGNAL


CS/D

Pump flow rate is obtained by adjusting pulse frequency (%) by digital controls
  • Proportional dosing pump to remote mA signal
  • Selection range 0/4...÷20mA or reverse
  • Constant modes operations
  • Strokes frequency adjustment 0÷100%
  • Microcontroller technology, display and digital controls
  • 2 LED display status: power, pulses and level
  • Level control (Level switch upon request)

PROPORTIONAL TO DIGITAL CONTACT


P/D

  • Proportional dosing pump to external digital pulses, (e.g.pulse water meters or equipment releasing voltage free pulse contacts)
  • Constant modes operations
  • Strokes frequency adjustment 0÷100%
  • Microcontroller technology, display and digital controls
  • 3 LED display status: power, pulses and level
  • Level control (Level switch upon request)
  • Available upon request PPM dosing mode

For available Pulse Water Meters

P/D+

  • Sequence strokes/ injection with flow sensor (latter on request)
  • Other characteristics as above MX P/D

PROPORTIONAL MODES:

  • Divider n1 (n= pulses received /1= injection
  • Multiplier 1xN (1=pulse received *N= injections)
  • Multiplier 1xN M (with Memory)
  • Pacing 1:1 (1 pulse received/1 injections)

MULTIFUNCTION DOSING MODE PUMP


MF

  • Multifunction dosing pumps including most dosing operations modes
  • Microcontroller technology, display LCD and digital controls
  • Strokes frequency adjustment 0÷100%
  • Proportional to external digital pulses: divider n : 1; multiplier 1xN
  • Proportional to external analog signal 0…4 mA÷20mA or reverse
  • PPM dosing mode
  • Constant mode with digital adjustment: imp/min; imp/hour; imp/day
  • Digital timer, weekly and daily programming
  • Sequence strokes/ injection with flow sensor (sensor on request)
  • Level alarm output contact: NO/NC
  • Level control (Level switch upon request)
  • Available with double level control
  • Available 12-24Vdc (limited flow rate range)

DOSING PUMP WITH BUILD-IN PROPORTIONAL MULTIPARAMETER CONTROLLER
CTRL3: pH – Redox (ORP) – Free chlorine


CTRL3

Three different controllers and a dosing pump into one enclosure with great advantage to stock only one model for 3 measuring parameters.
pH: measuring range 0÷14,00 pH (resolution 0,01pH)
RX (ORP): measuring range -1000÷ +1400 mV (resolution 1mV)
Free chlorine*: range 0÷20,00 ppm (resolution 0,1ppm)
*CL controller is suitable either with amperometric-potentiostatic membrane Chlorine sensors or open Chlorine cells (latter on request)
  • Microcontroller technology, back-lit LCD display, digital controls
  • Injection frequency adjustment
  • Connectors: BNC for electrode and 4 pole IP65 for CL sensors
  • 2 Reset modes: full reset - partial reset keeping calibration settings
  • Level control (Level switch upon request).
  • Proportional mode range value selection
  • Delay adjustment - Delay at powering ON (electrodes polarization)
  • Stroke length adjustment for injected volume regulation (only FX series)
  • Hysteresis regulation
  • Password setting
  • Calibration of mA output
  • 4÷20 mA output for chart recorder
  • Alarm functions: Over dosing alarm value to prevent excess of chemical injection
  • Alarm for minimum or Maximum time for reaching set point
  • Direct or Reverse mode (Alkaline or Acid, Oxidant or Reducing RX)
  • Stand-by mode for cleaning electrodes and sensors or re-calibration
  • Temperature measurement °C or °F
  • Suitable for Temperature probe PT100
  • Setting for proximity switch to stop operations in case of no water (instead of level)
  • Alarm functions and setting with relay output

DOSING PUMP WITH BUILD-IN PROPORTIONAL DUAL PARAMETER CONTROLLER
CTRL2: pH – Redox (ORP)


CTRL2

Two different controllers and a dosing pump into one enclosure with great advantage to stock only one model for 2 measuring parameters.
pH: measuring range 0÷14,00 pH (resolution 0,01pH)
RX: measuring range -1000÷ +1400 mV (resolution 1mV)
  • Microcontroller technology, back-lit LCD display, digital controls
  • Injection frequency adjustment
  • 2 Reset modes: full reset - partial reset keeping calibration settings
  • Stroke length adjustment for injected volume regulation (only FX serie)
  • Level control (Level switch upon request).
  • Proportional mode range value selection
  • Delay adjustment - Delay at powering ON (electrodes polarization)
  • Hysteresis regulation
  • Password setting
  • Direct or Reverse mode (Alkaline or Acid, Oxidant or Reducing RX)
  • Stand-by mode for cleaning electrodes and sensors or re-calibration